I've a mansard roof with steep sides with gables, and also a nearly flat major with a rubber roof. There aren't any vents, it hasn't been insulated right before I started focusing on it and possess two questions:

Of course, you'll nevertheless have thermal bridging through the rafters. But you won't have any dampness issues.

The code limitations on the usage of air-permeable insulation involving rafters were designed to circumvent the roof sheathing from rotting. When fiberglass batts are set up in unvented rafter bays, the batts permit moist indoor air to reach the chilly roof sheathing.

You've got plenty of restraints, and people restraints are foremost you to some convoluted pondering. In place of advising you to definitely adopt a series of compromises, I will describe the proper way to address your roof, even though the appropriate way is pricey.

Should your local climate isn't way too extreme it's in all probability okay to have just the R-10 foam more than the structural steel, Whilst there's some risk that the steel could sweat in cold climate. I'm assuming You furthermore may meant to insulate the 2x12 joist bays to Get the overall R-value to some reasonable degree.

an air barrier. If you intend to put in EnGard insulation batts within an unvented cathedral ceiling, you'll need to get a major layer of rigid foam insulation above the roof sheathing.

Be sure to enter any prior references company roofing near me (past consumers) that you may have labored with divided by typing Enter

That appears to be extremely appealing: go with R-30 within the underside in the deck at our house using a mix of fiberglass batts and XPS as I described previously mentioned, after which insert yet another R-ten (two" XPS) on the best facet after we tear down and re-roof? Unfortunately that looks like It is far too easy.

In the event you go in advance with your plan, you ought to include things like a sensible vapor retarder on the interior side of the assembly, to reduce the transport of humidity from the inside to your sheathing.

Therefore the question is: seal the stucco vents and incorporate the spray foam roof and Don't be concerned about condensation? There may be quite little small-hanging fruit in our variety of construction, In particular her comment is here on present households, Which explains why consumers are staying sucked in to the spray foam roof fraud.

I need to wonder In the event the failure within roofing company cincinnati the Image would've occured In case the hip and ridge was vented and almost everything else the identical?

We will give it a check out. Present is often a fourteen 12 months outdated roof with 2" of shut mobile roofing foam with an acrylic elastomeric coating.

By Martin Holladay

A different issue is, should I go on the same insulation assembly outside? The last picture demonstrates a significant ten' overhang. Really should I vent this exterior portion or seal the underside with the p.t. plywood deck with the closed-cell insulation?