This roof assembly appears to be like very cathedral but if i have an understanding of effectively its not vented in any respect, but has generous previously mentioned sheathing foam. Is this considered a vapour Risk-free assembly contemplating this post claims "Set up rigid foam insulation earlier mentioned the roof sheathing and air-permeable insulation involving the rafters.

I similar to the detail furnished but I would not simply call that a cathedral ceiling situation as it involves ceiling joists spanning at The underside on the roof rafters. I would call this an insulated attic.

The plan is to set up it (from the inside of the house) about a similar time the drywall is set up. I'll instruct my crew to be sure there are no air pockets from the purlin cavities & no air movement into your latter.

It appears like an outstanding plan. Depending on which kind of rigid foam you select, you are going to find yourself with insulation in the array of R-16 to R-24. While that's less than code necessities, It is really much, far better than what you have got now.

Many of my neighbors in this article have cathedral ceilings, no attics and Totally no insulation (essentially they have got aluzinc roofs on plywood with pine rafters).

I'm a homeowner with cathedral ceilings that ended up added during transforming and enlargement of my home within the late 90s. Only the ridge beam is exposed. The remainder of the ceiling is covered with drywall. In the decades There have been some condensation leak down the aspect of your ridge beam on some mornings in March/April.The home is about 4 miles through the coast in Southern Califonia, so zone 3b. You will find 4 recessed lights within the ceiling over the side of the beam that will get the condensation, but there are also lights about the side that is usually dry. There is absolutely no air con in the house. Warmth is made use of in the course of the evening only about a dozen nights a year, not in the condensation. Usually the Home windows are open. It appears the condensation exhibits up on mornings when there is not any marine layer (no clouds in the morning) and also the temperature heats up rather early following a extremely amazing night time. The situation ceiling faces east/west along with the condensation is within the east experiencing side on the beam. The roof roofing company savannah ga is black asphalt shingle. I know that there isn't any caulk/sealant between the side from the beam as well as position wherever the drywall butts against it, so You will find there's smaller air hole there.

Ideally, you want to have an airtight barrier above and below your fiberglass batts. If you're able to reach Individuals two air barriers, then wind-washing is just not a problem inside a roof like yours. (It might be in a very vented unconditioned attic, not surprisingly, Specifically near the soffits.)

The roof was shingles on t&g pine decking. Insulation was correct up versus that pine decking because 77 and is particularly 2014. Things seems like it absolutely was installed yesterday. Not a nasty location any where, no roof vents fully unvented roof.

My experience is that the dew position profile would find yourself during the XPS foam board, that's why a VB really should be placed on initially deck. To be able of assembly:

It is surely not limited to an R eighty Passive Home roof. Choose out the parallel chord trusses and slender it up.

Yesterday we blew the insulation and mounted the SIGA Majcoat on the CAPACES Leadership Institute. There was greater than eight,000 Cubic feet of insulation to setup, so our insulators had two of their blower trucks and a superb crew on website. They had been blowing cellulose as fast as they may and the the rain was heading our path. Lower than 45 minutes once the insulation was finished we experienced finished the Majcoat and ended up busy taping seams.

In the final summary it reads: "When you are using fluffy insulation, you need two air barriers: 1 down below the insulation, and just one above the insulation.

A different Predicament I am owning re: Ice & Drinking water Protect is that I was searching forward to eradicating the recently placed asphalt felt that is presently about the pine T&G and replacing it with a special roofing company profit margins product, as the asphalt scent in the felt is coming in the T&G ceiling and bothering me (just in the event I essential any proof that that ceiling is horribly air permeable...). But then I read inside the Grace Ice & H2o Shield set up Guidance that "Because of its slight asphaltic odor, never utilize Grace... Ice & Drinking water Shield... wherever the membrane is subjected to interior living areas." So if I substitute the felt with Ice & H2o Defend or an identical asphalt-based products, I'd almost certainly just be leaping through the hearth into the frying pan, odorwise.

I thanks for this impeccably timed blog, as I am now framing my semi-basic cathedral ceiling hip roof (with short ridge). I want to describe my depth and check out to comprehend wherever I'm on the right track plus much more importantly, exactly where I will likely have failures. Hope I'm able to amuse many of you...I sense similar to the a lot more I attempt to deal with a priority, the greater of websites a concern it results in being, and I absolutely don't desire to just take wonderful time, treatment, and detail to facilitate the demise of my roof.